The TM Series Sensor Timing Module is an economical system to start-stop processes in the event of equipment malfunctions due to overloads, over temperature of bearings, conveyor belt misalignment, conveyor overloads, storage bin over fills, etc.
Main CPU Housing
- 117VAC 1 AMP MAX 50/60HZ
- NEMA 3-4-12 All Steel Housing with Display Viewing Window
- Pre-punched for ¾ inch and ½ inch conduit inlets
- Epoxy Paint
- Removable Hinged Door with lock
Sensor Inputs
- Standard Unit designed for Normally Closed switches. Normally Open version available. (Consult factory to order)
- Voltage to sensor (12V DC)
- Supervised circuit detection kit supplied for sensor inputs: Supervised circuit will detect shorted leads.
CPU Printed Circuit Board
- Time Delay on user selects 0-30 seconds
- Time Delay off user selects 0-30 seconds
- Locking Mode- User selects ON or OFF
- Alarm-Time Delay On-User selects
- Relay Outputs-120VAC @ 5 Amp Dry Contracts
- RS232 Output
- TTL Output 0-5VDC
- The voltage and current to the sensors are fused which makes the system safe for all type environments.
- Sensor outputs are fused.
Overview
- The TM Series works in the fail safe mode. If system fails Relay outputs go to OPEN mode.
- The TM Series have supervised circuit capability that will detect sensor lead shorts versus the closed sensor circuit.
- The TM Series have Time Delay ON user set time adjustment 0-30 seconds.
With the built in alarm switch in the ON position a pre-warning that the Time
ON timer has started due to sensor activation. This alarm will sound until times
out and switches relay or sensor resets.
Time Delay
- Time Delay Off: User sets 0-30 seconds. In automatic Mode when sensor resets
time will begin counting. When timer times out relay will switch back to closed
position.
- Locking Mode: When time ON timer times out, relay switches to Open position.
Delay locks in this position until "Reset" push button is pressed.
CPU Display Board
- L.E.D. INDICATORS
- Solid Green-Sensor in normal position
- Flashing Green-Time on Timer activated
- Solid Red-Sensor in OPEN (fault) position
- Flashing Red-Time OFF Timer activated
- Solid Yellow (OFF) Supervised circuit not sensing and circuit faults
- Flashing Yellow-Sensor leads shorted (fault)
- Time ON Adjustment (set)
- Time OFF Adjustment (set)
There is a place to use the TM Series System in virtually all aspects of industry.
Some areas the TMGT-01 is used include the following:
- Green Houses
- Dairy Barns
- Swine Operations
- Chicken Houses
- Grain Storage
- Chemical Industry
- Feed Mills
- Flour Mills
- Food Processing
- Bakeries
- Concrete Plants
Some Typical Applications Include:
- Sense Conveyor Alignment
Sense conveyor belt misalignment. Allows conveyor to empty then shut down. Sense bearing over temperature: Allows process to finish then shut down.
- Sense Liquid Levels
Flow Control-When level is too high or low, flow will cut off until level drops or rises to normal. System will allow to restart or stop automatically.
- Equipment Startup/Slow Down
Use for equipment sequence start up or slow down.
- Start/Stop
Ventilation Fans
Dust Collection systems.
- Location/Position of Process Equipment
- Vent Temperature Control
Open/Close vent for air flow to control temperature in green houses.