| Motion and Temperature Together! | |||||||||||
MT 400 Series Motion Controller
Digital Display (Percentage)Three (3) second to start-time frame: Monitored equipment has (3) seconds from start to run. (The equipment does not have to reach operation speed). Monitors acceleration to (Normal) operation speed. If monitored equipment should overload before reaching (Normal) operation speed, shut down will occur before damaging monitored equipment. De-acceleration before reaching operating speed feature Status Indicators - L.E.D. 10% Speed Reduction - 20% Speed Reduction: Arm (will light when monitored equipment reaches 90% of normal speed during startup), Target. Outputs
Wiring
Digital Temperature Electronic Controls
Digital temperature equipment sensors can be used for hot bearing and/or belt misalignment sensing.
Model MT DT Back lighted LCD display Displays 16 characters by 2 lines - alphanumeric Supply Power Relay output 4 AMP SPST (N/O or N/C SELECT) Trip #1 Temperature Alarm adjustable (-15° to +230° F) Trip #2 Rate of rise adjustable (1° to 99° F) Signal Input Type T thermocouple (UNGROUNDED) 1 to 24 Inputs single ended (25 Pin Min. D) Scan Rate Adjustable from 1.0 to 4.0 seconds Scan is selectable for automatic or manual Each point can be operator programmed with alphanumeric characters Each alarm point can be turned ON or OFF Temperature display in Degree C or F Options RS485 - For remote operation (Input-Output) Isolated and fault protected Plug in connector for signal input - 24 inch pigtail for wire splice connections Trip #2 Rate of rise adjustable (1° to 99° F) |
|||||||||||

Digital Display (Percentage)